Zum Hauptinhalt springen

CreateAddress

Class Description

Method requires user to be of Type AuthorizationLevel::SUPERUSER

RPC Configuration

Rpc Name:

Plain: CreateAddress
Sha1: 7d1cb035f25f5de830f65598739a5744d6eb29d0
Rpc Call

RPCs can be called by their plain name or their SHA1 representation.

Rpc Parameters:

"thoroughfare" : string,
"thoroughfareNo" : string,
"city" : string,
"postalcode" : string,
"lat" : float,
"lon" : float,
"administrativArea" : string,
"country" : string = Deutschland,
"countryCode" : string = de

Requires Login:

true

Requires Context:

Context

The context providing parameter can either be a contagt-id (8-Bytes, Alphaumeric) or an integer as a building id. The context parameter name should make the choice obviouse, the type has not to be defined manually.

false

Requires WriteAccess:

WriteAccess

Only accounts that have an explicit write access to the defined context can execute this RPC, no matter if the authentication level matches or not.

true

Requires AuthenticationLevel:

Context

Authentication levels allow the SuperUser to define a by-RPC granular access configuration. If RPCs are chained in a single unified call and lenient is enabled, all allowed RPCs will be executed, while execution will fail entirely with lenient set to false.

SUPERUSER

Requires Subbuilding Merge Strategy:

SUBBUILDING_ONLY

Cache Configuration

Response Cache

All writing RPCs are not Cacheable, also Caching will be disabled by the paramters nocache and readonly.

Cache enabled:

false