Zum Hauptinhalt springen

LoadARFeaturePoints

Class Description

Save a new Augmented Reality Reference Image
@param int building_id The Buildings' context


@param float image_id The Identifier of the image to delete.


@return An Array of ARReferenceImage(s) or false

RPC Configuration​

Rpc Name:​

Plain: LoadARFeaturePoints
Sha1: 63a855aa121316ae4bd6f160dbf7912f603bc0eb
Rpc Call

RPCs can be called by their plain name or their SHA1 representation.

Rpc Parameters:​

"building_id" : int,
"floor" : int,
"minLat" : ?float = null,
"maxLat" : ?float = null,
"minLon" : ?float = null,
"maxLon" : ?float = null

Requires Login:​

true

Requires Context:​

Context

The context providing parameter can either be a contagt-id (8-Bytes, Alphaumeric) or an integer as a building id. The context parameter name should make the choice obviouse, the type has not to be defined manually.

true

Requires contextParamName:​

building_id

Has Named Parameters:​

true

Requires WriteAccess:​

WriteAccess

Only accounts that have an explicit write access to the defined context can execute this RPC, no matter if the authentication level matches or not.

false

Requires AuthenticationLevel:​

Context

Authentication levels allow the SuperUser to define a by-RPC granular access configuration. If RPCs are chained in a single unified call and lenient is enabled, all allowed RPCs will be executed, while execution will fail entirely with lenient set to false.

STANDARD_USER

Requires Subbuilding Merge Strategy:​

REPLACE

Cache Configuration​

Response Cache

All writing RPCs are not Cacheable, also Caching will be disabled by the paramters nocache and readonly.

Cache enabled:​

true

Cache Time to Live:​

60

Sample Request​

->

{
"building_id": 131,
"floor": 0,
"minLat": -90,
"minLon": -180,
"maxLat": 90,
"maxLon": 180
}